Test Kit Alkalinity P & M

Test Kit Alkalinity P & M

Determination of Alkalinity P & M. Range 0 - 400 ppm.

Product description

TEST KIT ALKALINITY P & M is suitable for measuring alkalinity P & M in any boiler type. Designed to accompany ALKALINITY CONTROL in high-pressure boilers and BOILER TREAT COMBI or BOILER TREAT ONE SHOT in low- and middle-pressure boilers.

Boiler testing pack:

• TEST KIT ALKALINITY P & M

TEST KIT CHLORIDE

TEST KIT OXYGEN/HYDRAZIDE DEHA

TEST KIT PHOSPHATE (high-pressure boilers)

TEST KIT TOTAL HARDNESS

REAGENT PH-PAPER 0-14

Number of uses: Between 150 – 187

Recommended use with:

ALKALINITY CONTROL*

BOILER TREAT COMBI*

BOILER TREAT ONE SHOT*

*Above chemicals should not be used in conjunction

Directions for use

1. Fill the test jar to the 20 ml mark with cooled sample.
2. Add 4 drops of reagent PA1. The sample should turn pink. If it does not, terminate the test and report a result of zero.
3. Add drops of reagent PA2 one at a time with gentle mixing until the pink colour disappears. Count the number of drops used.
4. Each drop is equivalent to 40 mg/l P-alkalinity, expressed as CaCO3.
5. Retain the sample after the alkalinity test as this may be used for the chloride determination if required.
6. Total alkalinity (as CaCO3): for total alkalinity, replace reagent PA2 with TA4 in step 2. Colour change in step 3 is from blue to orange.

Drops of reagent PA2

P-alkalinity as mg/l CaCO3

Refer to “Treatment Guides” for ideal concentration, general information only is stated below

1

40

Low alkalinity; increase product dose
to achieve additional 100 mg/l P-alkalinity

2

80

3

120

4

160

Correct P-alkalinity level

5

200

6

240

7

280

Reduce by increased blowdown

8

320

9

360

10

400

Instruction video:

Test Kit Alkalinity P & M contents

• 1x 65 ml Plastic Test Bottle
• 1x 10 ml Syringe
• 1x 30 ml PA1 Indicator
• 2x 30 ml PA2 High Range Titrant
• 1x 30 ml TA4 Indicator

Features & Benefits

  • Easy to use
  • Reliable & accurate results
  • Easy management & storing design
  • Uniform reagent consumption
  • Reagents in excepted quantities making the kit normal-post sendable
This information is not to be taken as a warranty or representation for which Vecom Marine assumes legal responsibility.
The information is offered solely for your consideration, investigation and verification.