Product description
TEST KIT ALKALINITY P & M is suitable for measuring alkalinity P & M in any boiler type. Designed to accompany ALKALINITY CONTROL in high-pressure boilers and BOILER TREAT COMBI or BOILER TREAT ONE SHOT in low- and middle-pressure boilers.
Boiler testing pack: • TEST KIT ALKALINITY P & M • TEST KIT OXYGEN/HYDRAZIDE DEHA • TEST KIT PHOSPHATE (high-pressure boilers) |
Number of uses: Between 150 – 187 |
Recommended use with: *Above chemicals should not be used in conjunction |
Directions for use
1. Fill the test jar to the 20 ml mark with cooled sample.
2. Add 4 drops of reagent PA1. The sample should turn pink. If it does not, terminate the test and report a result of zero.
3. Add drops of reagent PA2 one at a time with gentle mixing until the pink colour disappears. Count the number of drops used.
4. Each drop is equivalent to 40 mg/l P-alkalinity, expressed as CaCO3.
5. Retain the sample after the alkalinity test as this may be used for the chloride determination if required.
6. Total alkalinity (as CaCO3): for total alkalinity, replace reagent PA2 with TA4 in step 2. Colour change in step 3 is from blue to orange.
Drops of reagent PA2 |
P-alkalinity as mg/l CaCO3 |
Refer to “Treatment Guides” for ideal concentration, general information only is stated below |
1 |
40 |
Low alkalinity; increase product dose |
2 |
80 |
|
3 |
120 |
|
4 |
160 |
Correct P-alkalinity level |
5 |
200 |
|
6 |
240 |
|
7 |
280 |
Reduce by increased blowdown |
8 |
320 |
|
9 |
360 |
|
10 |
400 |
Instruction video:
Test Kit Alkalinity P & M contents
• 1x 65 ml Plastic Test Bottle
• 1x 10 ml Syringe
• 1x 30 ml PA1 Indicator
• 2x 30 ml PA2 High Range Titrant
• 1x 30 ml TA4 Indicator
Features & Benefits
- Easy to use
- Reliable & accurate results
- Easy management & storing design
- Uniform reagent consumption
- Reagents in excepted quantities making the kit normal-post sendable