Product description
TEST KIT TOTAL HARDNESS is suitable for measuring total hardness in any water system. Hardness is largely made up by calcium and magnesium carbonates. High levels of hardness will cause scaling in water systems and will prevent foam formation when soap is agitated in water, increasing soap consumption.
Boiler testing pack: • TEST KIT TOTAL HARDNESS • TEST KIT OXYGEN/HYDRAZIDE DEHA • TEST KIT PHOSPHATE (high-pressure boilers) |
Number of uses: Between 100 – 200 |
Recommended actions: The amount of hardness must be lower than 2 ppm at all times. An appropriate boiler treatment programme can help maintain that level. In presence of scale DESCALING LIQUID EXTRA is advised. |
Directions for use
1. Take sample for expected range.
2. Add 4 drops of TH2.
3. Add 3 drops of TH5.
4. Count drops of TH3 until pure blue.
5. To calculate your results multiply the number of drops added to sample by the Sample Size (SS) factor.
Titrant Used – TH3
Anticipated Range |
Sample Size (ml) |
SS Factor |
0 – 15 |
40 |
0.5 |
10 – 30 |
20 |
1 |
20 – 60 |
10 |
2 |
Hardness Total (mg/l) ppm = Number of drops x SS factor.
Instruction video:
Test Kit Total Hardness contents
• 1x 65 ml Plastic Test Bottle
• 1x 10 ml Syringe
• 1x 30 ml TH2 Total Hardness Buffer
• 1x 30 ml TH5 Total Hardness Indicator
• 1x 65 ml TH3 Low Range Titrant
Features & Benefits
- Can be used in any water system
- Easy to use
- Reliable & accurate results
- Easy management & storing design
- Reagents in excepted quantities making the kit normal-post sendable